When calling code2flow within python (i.e. not via cmd line), the default logging config is overwritten:
logging.basicConfig(format="Code2Flow: %(message)s", level=level)

This is a bit annoying, as it requires to reconfigure logging after calling code2flow to remove Code2Flow prefix.

Activity

  1. added 2 commits that reference this issue on May 8, 2024
    dbfd415
    a1b5946
  2. pawamoy commented on Jul 12, 2024

    @pawamoy

    Yep, agree. Code2Flow should only call logging.basicConfig() from its main entrypoint, not from the code2flow function, which is documented as programmatic use.

  3. pawamoy commented on Jul 12, 2024

    @pawamoy

    Oh, worse than that, it uses the root logger, so we can't even disable logging for code2flow only with something like this:

    logging.getLogger("code2flow").setLevel(logging.CRITICAL + 1)

    Code2Flow should get its own logger with logger = logging.getLogger("code2flow") 🙂

  4. pawamoy commented on Jul 12, 2024

    @pawamoy

    I was able to disable code2flow.engine's logging with this:

    from unittest.mock import MagicMock
    from code2flow import engine
    
    engine.logging = MagicMock()
  5. maxjeblick commented on Jul 15, 2024